6. Modbus

ASCII

251

Modbus

(4) Sample query

A sample query that executes home return operation of a controller of axis No. 0 is shown below.

Query:

First time:

01 05 04 0B 00 00 EB --- Set normal status

Second time: 01 05 04 0B FF 00 EC --- Execute home return

Field

ASCII mode 8-bit data

Converted ASCII

code data [H]

Start

‘:’

3A

Slave address [H]

‘0’, ‘1’

3031

Function code [H]

‘0’, ‘5’

3035

Start address [H]

‘0’, ‘4’, ‘0’, ‘B’

30343042

Changed data [H]

First time: ‘0’, ‘0’, ‘0’, ‘0’

Second time: ‘F’, ‘F’, ‘0’, ‘0’

(Send data twice to set the edge.)

30303030

46463030

Error check [H]

First time: ‘E’, ‘B’ (In accordance with LRC

calculation)

Second time: ‘E’, ‘C’ (In accordance with

LRC calculation)

4542

4543

End

‘CR’, ‘LF’

0D0A

If the change is successful, the response message will be the same as the query.