Modbus – IAI America ROBO Cylinder Series User Manual

Page 290

Advertising
background image

6. Modbus

ASCII

282

Modbus

(6) Example of use

Examples of different operations are shown in [1] to [7] below.

[1] Move by changing the target position. (All data other than the target position are the default

values of their respective parameters.)

Conditions: The operation conditions conform to the default speed, default

acceleration/deceleration and default positioning band set by the controller’s user

parameters. Only the target position is changed to move the actuator.

Supplement: Controller’s user parameters

x

Default speed (parameter No. 8) o Maximum speed of the applicable actuator as specified

in the catalog

x

Default acceleration/deceleration (parameter No. 9) o Rated acceleration of the applicable

actuator as specified in the catalog

x

Default positioning band (parameter No. 10) o Default value = 0.1 mm

Write the target position specification register (9900

H

)

(Example 1)

Start of movement

(Example 1) Target position: 50 mm

Target

position

[mm]

Positioning

band

[mm]

Speed

[mm/s]

Acceleration/

deceleration

[G]

Push

[%]

Control flag

50

Need not be set.

„

Query : 01 10 9900 0002 04 0000 1388 B5[CR][LF]

„

Response : 01 10 9900 0002 54[CR][LF]

--- The query message is copied, except for the number of bytes and new data, and returned

as a response.

„ᴾ

Breakdown of Query Message

Field

ASCII mode

fixed character string

Converted ASCII

code data [H]

Remarks

Header

‘:’

3A

Slave address

‘0’, ‘1’

3031

Axis number + 1

Function code

‘1’, ‘0’

3130

Start address

‘9’, ‘9’, ‘0’, ‘0’

39393030

The start address is the target position

specification register 9900

H

.

Number of registers

‘0’, ‘0’, ‘0’, ‘2’

30303032

Specify 9900

H

through 9901

H

as the

addresses to be written.

‘0’, ‘4’

3034

2 (registers) × 2 = 4 (bytes) o 4

H

Number of bytes

‘0’, ‘0’, ‘0’, ‘0’

30303030

Changed data 2 [H]

‘1’, ‘3’, ‘8’, ‘8’

31333838

50 [mm] x 100 = 5000 o 1388

H

Error check

‘B’, ‘5’

4235

LRC checksum calculation result o B5

H

Trailer

‘CR’, ‘LF’

0D0A

Total number of bytes

27