Modbus – IAI America ROBO Cylinder Series User Manual

Page 93

Advertising
background image

5. Modbus RTU

85

Modbus

5.3.10 I/O Port Output Signal Status Reading<<DOPM>>

(1) Function

This query reads the port output value of the RC controller regardless of the PIO pattern.

(2) Query format

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Start address [H]

2

9004

Output port monitor register

Number of registers [H]

2

0001

Reading addresses 9004

H

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

8

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of data items

(number of bytes)

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address [H]

1

Arbitrary

Axis number + 1 (01

H

to 10

H

)

Function code [H]

1

03

Register reading

Number of data bytes [H]

1

02

Reading 1 register = 2 bytes

Data 1 [H]

2

D0 output value

Port output value [Hex]

Error check [H]

2

CRC (16 bits)

End

None

Silent interval

Total number of bytes

7