Modbus – IAI America ROBO Cylinder Series User Manual

Page 177

Advertising
background image

5. Modbus RTU

169

Modbus

[7] Note (changing positioning band during movement)

The positioning band cannot be changed while the actuator is moving.

Conditions: Change the target position, speed and acceleration/deceleration each time the

actuator is moved, with the positioning band changed at a given timing during

movement.

(Cannot be changed. If data is written, the data is reflected in the next

positioning.)

Write the target position specification register (9900

H

) through

acceleration/deceleration specification register (9906

H

)

Start normal operation

Write the positioning band specification registers (9902

H

and 9903

H

)

The actuator continues with the normal operation at the original positioning band setting

Supplement: Writing the positioning band specification registers alone cannot effect an actual

movement command.

Therefore, the data changed by writing the positioning band specification

registers (9902

H

and 9903

H

) will become effective when the next movement

command is executed.