Modbus – IAI America ROBO Cylinder Series User Manual

Page 84

Advertising
background image

5. Modbus RTU

76

Modbus

(4) Query sample

A sample query that reads the total FAN driving time (addresses 842E

H

to 842F

H

) of a controller

with axis No. 0 is shown below.

z

Query (silent intervals are inserted before and after the query)

01 03 84 2E 00 02 8C F2

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Start address [H]

842E

Number of registers [H] 0002

Error check [H]

8CF2 (in accordance with

CRC calculation)

End

Silent interval

The response to the query is as follows.

z

Response (silent intervals are inserted before and after the response)

01 03 04 00 00 02 AF BB 2F

Field

RTU mode

8-bit data

Start

Silent interval

Slave address [H]

01

Function code [H]

03

Number of data bytes [H] 04 (4 bytes = 2 registers)

Data 1 [H]

00 00

Data 2 [H]

02 AF

Error check [H]

BB2F (in accordance with CRC calculation)

End

Silent interval

The total FAN driving time is “000002AF

H

” o Convert into decimal number o 687[sec]

Note The data of the response example is simply an example and will vary depending on

various conditions.