4 various setting before starting communication, Modbus – IAI America ROBO Cylinder Series User Manual

Page 32

Advertising
background image

3. Specifications

24

Modbus

3.4 Various Setting before Starting Communication

Fig. 3.7

If multiple controllers are

connected, set the axis

numbers

[refer to section 3.5].

Set the communication

speed of each controller

[refer to section 3.6].

Completion of wiring

Only necessary to set

once at first launch

Launch the network

(start up the master and

each controller).

Disable PIO startup.

[RTU: Refer to section 5.4.15]

[ASCII: Refer to section 6.5.15]

(Note) Not necessary if

communication is only

used to monitor each

controller

All controllers disabled?

Turn on the servo of the axis to

be activated.

[RTU: Refer to section 5.4.3]

[ASCII: Refer to section 6.5.3]

Return the axis to be activated to

home.

[RTU: Refer to section 5.4.7]

[ASCII: Refer to section 6.5.7]

* Not necessary in case of absolute

specification

Main loop:

Normal processing

(position move, etc.)

m

The setup is complete at this

point. Subsequent steps are

processing steps performed

part of normal operations.