Modbus – IAI America ROBO Cylinder Series User Manual

Page 227

Advertising
background image

6. Modbus

ASCII

219

Modbus

6.4.14 Controller Status Signal Reading 4 <<STAT>>

(1) Function

This query reads the internal operation status of the controller.

[Refer to “4.3.2 (15) Data of system status register.”]

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Start address [H]

4

‘9’, ‘0’, ‘0’, ‘8’

System status register

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘2’

Reading addresses 9008

H

to

9009

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Internal controller status

Number of data bytes [H]

2

‘0’, ‘4’

Reading 2 registers

= 4 bytes.

Data [H]

8

System status

System status [Hex]

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

19