Modbus – IAI America ROBO Cylinder Series User Manual

Page 239

Advertising
background image

6. Modbus

ASCII

231

Modbus

6.4.20 Zone Output Signal Status Reading <<ZONS>>

(1) Function

This query reads the status of zone output.

[Refer to 4.3.2 (17), “Data of zone status registers.”]

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Start address [H]

4

‘9’, ‘0’, ‘1’, ‘3’

Zone status query

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘1’

Reading address 9013

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters

ASCII mode

character string

(fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Number of data bytes [H]

2

‘0’, ‘2’

Reading 1 register

= 2 bytes

Data [H]

4

Zone status

Refer to 4.3.2 (17), “List

table.”

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

15