Modbus – IAI America ROBO Cylinder Series User Manual

Page 72

Advertising
background image

5. Modbus RTU

64

Modbus

(3) Query format

In a query message, specify the address of the register from which to start reading data, and

number of bytes in registers to be read.

1 register (1 address) = 2 bytes = 16-bit data

Field

RTU mode

8-bit data

Number of data items

(number of bytes)

Remarks

Start

None

Silent interval

Slave address [H]

Arbitrary

1

Axis No. + 1 (01

H

to 10

H

)

Function code [H]

03

1

Register reading code

Start address [H]

Arbitrary

2

Refer to 5.3.1 (2),

”Start address list”

Number of registers [H]

Arbitrary

2

Refer to the start address

list.

Error check [H]

CRC (16 bits)

2

End

None

Silent interval

Total number of bytes

8

(4) Response format

Field

RTU mode

8-bit data

Number of data items

(number of bytes)

Remarks

Start

Silent interval

Slave address [H]

Arbitrary

1

Axis No. + 1 (01

H

to 10

H

)

Function code [H]

03

1

Register reading code

Number of data bytes [H]

1

Total number of bytes of

registers specified in the

query

Data 1 [H]

Number of bytes of

register specified in the

query

Data 2 [H]

Number of bytes of

register specified in the

query

Data 3 [H]

Number of bytes of

register specified in the

query

Data 4 [H]

Number of bytes of

register specified in the

query

:

:

:

:

Error check [H]

CRC (16 bits)

2

Silent interval

End

None

Total number of bytes

256 max.