6. Modbus

ASCII

223

Modbus

6.4.16 Current Ampere Reading <<CNOW>>

(1) Function

The monitored data of motor current is indicated in mA.

The torque current command value is stored.

(2) Query format

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Start address [H]

4

‘9’, ‘0’, ‘0’, ‘C’

Current ampere monitor

Number of registers [H]

4

‘0’, ‘0’, ‘0’, ‘2’

Reading addresses 900C

H

to 900D

H

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

17

(3) Response format

A response message contains 16 bits of data per register.

Field

Number of characters ASCII mode character

string (fixed)

Remarks

Header

1

‘:’

Slave address [H]

2

Arbitrary

Axis number + 1

(01

H

to 10

H

)

Function code [H]

2

‘0’, ‘3’

Reading registers

Number of data bytes [H]

2

‘0’, ‘4’

Reading 2 registers

= 4 bytes

Data [H]

8

Motor current monitor Motor current monitor [Hex]

Indicated in mA.

Error check [H]

2

LRC calculation result

Trailer

2

‘CR’, ‘LF’

Total number of bytes

19