5. Modbus RTU

163

Modbus

(Example 4)

Move in the incremental mode by setting the pitch to 10 mm.

Pitch

[mm]

Positioning

band

[mm]

Speed

[mm/s]

Acceleration/

deceleration

[G]

Push

[%]

Control flag

10

0.1

100

0.3

0

Incremental

(bit3 = 1)

„

Query: 01 10 9900 0009 12 0000 03E8 0000 000A 0000 2710 001E 0000 0008 F3A0

„

Response: 01 10 9900 0009 2E93

--- The query message is copied, except for the number of bytes and new data, and returned

as a response.


„ᴾ

Breakdown of Query Message

Field

RTU mode

8-bit data

Remarks

Start

None

Silent interval

Slave address

01

H

Axis No. 0 + 1

Function code

10

H

Start address

9900

H

The start address is the target position specification

register 9900

H

.

Number of registers

0009

H

Specify 9900

H

through 9908

H

as the addresses to be

written.

Number of bytes

12

H

9 (registers) x 2 = 18 (bytes) o 12

H

0000

H

All upper bits of the 32-bit data are 0.

New data 1, 2

(target position)

Input unit (0.01 mm)

03E8

H

10 [mm] × 100 = 1000 o 03E8

H

0000

H

All upper bits of the 32-bit data are 0.

New data 3, 4

(positioning band)

Input unit (0.01 mm)

000A

H

0.1 [mm] × 100 = 10 o 000A

H

0000

H

All upper bits of the 32-bit data are 0.

New data 5, 6 (speed)

Input unit (0.01 mm/sec)

2710

H

100 [mm/s] × 100 = 10000 o 2710

H

New data 7

(acceleration/deceleration)

Input unit (0.01 G)

001E

H

0.3 [G] × 100 = 30 o 001E

H

New data 8 (push)

Input unit (%)

0000

H

0 [%] o 0

H

New data 9 (control flag)

0008

H

(Incremental setting)

1000b o 0008

H

Error check

F3A0

H

CRC check calculation result o F3A0

H

End

None

Silent interval

Total number of bytes

27