Modbus – IAI America ROBO Cylinder Series User Manual

Page 30

Advertising
background image

3. Specifications

22

Modbus

(2) Wiring

Fig. 3.5

Nth slave

(N = maximum 16 slaves)

SA

SGA
SGB
GND

SGA
SGB
GND

SGA

SDA

SDB
PDA

PDB

SGB
GND

B5

1
2
3
4

1
2
3
4

1
2
3
4

1
2
3

1
2
7

1
2
7

4

1
2
3
4

1
2
3
4

1
2
3
4

1
2

1
2

3

7

4

SB B6

RS485 connectors

Transmission data+

Transmission data-

Reception data+

Reception data-

2-pair shielded cables

Recommended cables:

Taiyo Cabletech HK-

SB/20276xL 2P x AWG22

4-directional junction (5-1473574-4 made by AMP)

Please note that some PLCs

are configured such that SDA

is the negative terminal of the

transmission data and SDB is

the positive terminal (in this

case, RDA is the negative

terminal of the reception data

and RDB is the positive

terminal).

Please refer to “3.3

Communication Connector Pin

Assignment of PLC and PC”

for pin assignment on the PLC

side.

To (2)

e-CON connector (3-1473562-4 made by AMP)

Housing color: Green

Controller link cable

CB-RCB-CTL002

Yellow

Orange

Blue

Yellow

Orange

Blue

e-CON connector (3-1473562-4 made by AMP)

Housing color: Orange

4-directional junction

(5-1473574-4 made by AMP)

2-pair shielded cables

Recommended cables:

Taiyo Cabletech

HK-SB/20276xL

2P x AWG22

From (2)

Determine the terminating

resistance value according

to the specification on the

master (host) side

(PLC, RS232C œ RS485

converter in case of PC).

ERC3 power supply I/O cable

CB-ERC3P-PWBIO**

*

e-CON connector (3-1473562-4 made by AMP)

Housing color: Green

Controller link cable

CB-RCB-CTL002

Yellow

Orange

Blue

Nth slave (N = maximum 16 slaves)

Green
Brown 1

e-CON connector (3-1473562-4 made by AMP)

Housing color: Orange

Note Connection of ERC3-SE

1) A cable (CB-ERC3-PMB10) is required

separately.

2) MEC Mode Type cannot be connected.

3) Connection cannot be established via PIO

Converter.

Nth slave

(N = maximum 16 slaves)

Caution Make sure to use the common 0 V line of

the 24 V power supply for each controller

(other than SCON).

For ROBONET connection, refer to the

separate ROBONET Operation Manual.

PLC

PCON/ACON/SCON

Nth slave (N = maximum 16 slaves)

Advertising