Protections of the unit itself, Xiii, Cnc 8070 – Fagor America CNC8070 User Manual

Page 24

Advertising
background image

XIII

CNC 8070

Saf

e

ty

condi

ti

on

s

(S

OFT

V03.0

X

)

XII

It is recommended, whenever possible, to install the CNC away from coolants,
chemical product, blows, etc. that could damage it.

T his unit complies with the European directives on electromagnetic
compatibility. Nevertheless, it is recommended to keep it away from sources of
electromagnetic disturbance such as:

Powerful loads connected to the same AC power line as this equipment.

Nearby portable transmitters (Radio-telephones, Ham radio transmitters).

Nearby radio/TV transmitters.

Nearby arc welding machines.

Nearby High Voltage power lines.

Etc.

‡ Enclosures.

The manufacturer is responsible of assuring that the enclosure involving the
equipment meets all the currently effective directives of the European
Community.

‡ Avoid disturbances coming from the machine tool.

The machine-tool must have all the interference generating elements (relay
coils, contactors, motors, etc.) uncoupled.

‡ Use the proper power supply.

Use an external regulated 24Vdc power supply for the keyboard and the remote
modules.

‡ Grounding of the power supply.

The zero volt point of the external power supply must be connected to the main
ground point of the machine.

‡ Analog inputs and outputs connection.

It is recommended to connect them using shielded cables and connecting their
shields (mesh) to the corresponding pin (see chapter 1 in the Installation
Manual).

‡ Ambient conditions.

The working temperature must be between +5ºC and +45ºC (41ºF and 113ºF)

The storage temperature must be between -25ºC y 70ºC (-13ºF y 158ºF)

‡ Monitor enclosure.

Make sure that the gaps between the Central Unit and each wall of the enclosure
are respected as indicated in chapter 1 of the Installation Manual.

Use a DC fan to improve enclosure ventilation.

‡ Main AC power switch.

This switch must be easy to access and at a distance between 0.7 and 1.7 m
(2.3 and 5.6 ft) off the floor.

PROTECTIONS OF THE UNIT ITSELF

‡ Remote modules.

All the digital inputs and outputs have galvanic isolation via optocouplers
between the CNC circuitry and the outside.

Advertising