It is recommended, whenever possible, to install the CNC away from coolants,
chemical product, blows, etc. that could damage it.
T his unit complies with the European directives on electromagnetic
compatibility. Nevertheless, it is recommended to keep it away from sources of
electromagnetic disturbance such as:
• Powerful loads connected to the same AC power line as this equipment.
• Nearby portable transmitters (Radio-telephones, Ham radio transmitters).
• Nearby radio/TV transmitters.
• Nearby arc welding machines.
• Nearby High Voltage power lines.
• Etc.
Enclosures.
The manufacturer is responsible of assuring that the enclosure involving the
equipment meets all the currently effective directives of the European
Community.
Avoid disturbances coming from the machine tool.
The machine-tool must have all the interference generating elements (relay
coils, contactors, motors, etc.) uncoupled.
Use the proper power supply.
Use an external regulated 24Vdc power supply for the keyboard and the remote
modules.
Grounding of the power supply.
The zero volt point of the external power supply must be connected to the main
ground point of the machine.
Analog inputs and outputs connection.
It is recommended to connect them using shielded cables and connecting their
shields (mesh) to the corresponding pin (see chapter 1 in the Installation
Manual).
Ambient conditions.
The working temperature must be between +5ºC and +45ºC (41ºF and 113ºF)
The storage temperature must be between -25ºC y 70ºC (-13ºF y 158ºF)
Monitor enclosure.
Make sure that the gaps between the Central Unit and each wall of the enclosure
are respected as indicated in chapter 1 of the Installation Manual.
Use a DC fan to improve enclosure ventilation.
Main AC power switch.
This switch must be easy to access and at a distance between 0.7 and 1.7 m
(2.3 and 5.6 ft) off the floor.
PROTECTIONS OF THE UNIT ITSELF
Remote modules.
All the digital inputs and outputs have galvanic isolation via optocouplers
between the CNC circuitry and the outside.