13.3.1 Interface description
The screen of the circularity test looks like this, with two clearly different parts. A
graphics window that shows the result of the test and a data area for interacting with
the system.
The graphics window
It is the area that shows, graphically, the result of the test.
The graphic shows the two moving axes and the theoretical circle of the interpolation
that will be carried out. As the test is being run, the positioning error at each point
is drawn on the circle. This error is shown projected radially.
Superimposed on the graphics, it shows the following additional data that is updated
by the CNC.
• The real coordinates of the axes.
• Programmed feedrate and % applied.
• Diameter of the displayed circle.
• Maximum and minimum error over the theoretical radius and angular position
where it has been detected.