13.

SETUP ASSI

STANCE

O

s

c

illo

s

c

o

p

e

(S

OFT

V03.0

X

)

278

Variables that may be modified at the Sercos drive

Besides the parameters shown in the previous table, the user may access any
variable having a writing permission if he knows its name. To do this, use the following
nomenclature:

Indicate the axis, the name of the parameter and the set separated by a period.

When modifying any parameter of the previous table, the change is effective
immediately without having to reset or restart the unit even when there is a program
in execution.

The drive parameters modified with this method are functional immediately, but these
values will be lost when the drive is turned off. Use the "Save to flash" option to
maintain the modified values of those machine parameters.

Drive

Name

Update

CP1

CP1.axis

Immediate

CP2

CP2.axis

Immediate

CP3

CP3.axis

Immediate

CP30

CP30[set].axis

Immediate

CP31

CP31[set].axis

Immediate

CP32

CP32[set].axis

Immediate

NP1

NP1.axis

Immediate

RP1

RP1.axis

Immediate

RP2

RP2.axis

Immediate

RP3

RP3.axis

Immediate

RP4

RP4.axis

Immediate

RP51

RP51.axis

Immediate

RP52

RP52.axis

Immediate

RP53

RP53.axis

Immediate

RP54

RP54.axis

Immediate

SP1

SP1[set].axis

Immediate

SP2

SP2[set].axis

Immediate

SP50

SP50.axis

Immediate

SP51

SP51.axis

Immediate

TP10

TP10.axis

Immediate

TP11

TP11.axis

Immediate

TP12

TP12.axis

Immediate

TP13

TP13.axis

Immediate

TP14

TP14.axis

Immediate