Cnc 8070 – Fagor America CNC8070 User Manual

Page 308

Advertising
background image

‡ ‡ ‡

‡ ‡ ‡

‡ ‡ ‡

‡ ‡ ‡

Operating manual

CNC 8070

13.

SETUP ASSI

STANCE

O

s

c

illo

s

c

o

p

e

(S

OFT

V03.0

X

)

274

Focus on the "C1" or "C2" field

Cursors "C1" and "C2" may be used to analyze each signal of the last data capture.

These two cursors may be used to obtain the position in milliseconds of each signal
and the time difference between them "

".

When the focus is on one of the fields "C1" or "C2", the following vertical softkeys will
appear.

Focus on the "parameter name" field

As with variables, by selecting the various parameters, it is possible to change their
names and values.

When pressing "Enter" after changing the name of a parameter, use the up, down,
left and right arrow keys to move the focus to the next field to change the value of
that parameter. After changing the parameter value and pressing "Enter", the focus
does not go on to the next field. Use the arrow keys to go on to the next parameter.

When the focus is on this field, the 4 vertical softkeys will be:

Takes the cursor to the beginning.

Takes the cursor to the end.

Takes the cursor to the trigger. If there is no trigger, it will go to the center of the window.

Moves the cursor to the left.

Moves the cursor to the right.

It increases the value of the parameter in the amount indicated on the configuration
screen.

It decreases the value of the parameter in the amount indicated on the configuration
screen.

It resets the parameter to its default value.

It validates the value given to the parameter.

From the "CONFIG" mode, a screen may be accessed where it is possible to
define the list of parameters to be displayed.

i

Advertising