4 save the can configuration for the start-up test, Save the can configuration for the start-up test, Cnc 8070 – Fagor America CNC8070 User Manual
Page 355
Operating manual
CNC 8070
DI
AG
NOSI
S
Sav
e
t
he CAN
c
onf
ig
ur
at
ion f
o
r t
he st
ar
t-
up t
e
s
t.
15.
(S
OFT
V03.0
X
)
321
15.4
Save the CAN configuration for the start-up test.
Saving a CAN configuration to a file serves to check the CAN configuration is correct
when starting the system up. The CAN configuration must only be saved to a file after
having verified that it is correct.
Save the CAN configuration.
When the CAN bus level is selected, it shows the
SAVE
softkey that may be used to
save the current CAN configuration. The configuration is saved in the file C:\Cnc8070
\mtb \data \canData.tab.
This file contains the number of groups present in the bus, the number of modules,
the number of inputs and outputs, etc.
Verify the CAN configuration during power-up.
To verify the configuration, the information must be previously saved to the file
canData.tab.
During the power-up process, the data saved in the canData.tab file is compared with
the data read during power-up. If when comparing the data, they are not the same,
the corresponding error message is issued.
"The CAN configuration is not the same as the one saved in the file"
Once the error is detected, it will keep coming up even after a reset. There two ways
to correct the error:
• Power up the CNC again with the original CAN configuration; the one saved in
the canData.tab file
• Save the new CAN configuration. The CAN configuration must only be saved to
a file after having verified that it is correct.