CNC 8070

SETUP ASSI

STANCE

O

s

c

illo

s

c

o

p

e

13.

(S

OFT

V03.0

X

)

271

Trigger data

In this area, the user may select the trigger conditions. The options offered by this
trigger data area are:

Trigger

It indicates when the data capture begins.

If not selected, the data capture begins as soon as the user gives the command to
begin. The "Flank", "Level" and "Position" data are ignored.

If selected, the trigger condition must be specified with the "Flank", "Level" and
"Position" data.

Channel

It indicates which variable or channel (CH1, CH2, CH3, CH4) is to be used as
reference or trigger condition.

Flank

It may be up-flank (leading edge) or down-flank (trailing edge).

It is taken into account when trigger has been selected.

Trigger level

It sets the value to be assumed by the variable to start capturing data.

It is taken into account when trigger has been selected.

Position (%)

It is taken into account when Trigger has been selected.

It is defined as a percentage, between 0% and 100%. It indicates the number of
samples to be taken before the Trigger. For example, a 10% position indicates that
10% of the total number of programmed samples will be taken before the Trigger and
the remaining 90% after that instant.

The Trigger condition is evaluated after gathering the indicated % of samples. If the
position is defined as 50% and the Trigger condition takes place after taking 10% of
the samples, it is ignored until capturing 50% of the samples.

Machine parameters to be set

In this area of the data window, it is possible to directly change the values of up to
20 machine parameters to be adjusted.