Cnc 8070 – Fagor America CNC8070 User Manual
Page 305

Operating manual
CNC 8070
SETUP ASSI
STANCE
O
s
c
illo
s
c
o
p
e
13.
(S
OFT
V03.0
X
)
271
Trigger data
In this area, the user may select the trigger conditions. The options offered by this
trigger data area are:
Trigger
It indicates when the data capture begins.
If not selected, the data capture begins as soon as the user gives the command to
begin. The "Flank", "Level" and "Position" data are ignored.
If selected, the trigger condition must be specified with the "Flank", "Level" and
"Position" data.
Channel
It indicates which variable or channel (CH1, CH2, CH3, CH4) is to be used as
reference or trigger condition.
Flank
It may be up-flank (leading edge) or down-flank (trailing edge).
It is taken into account when trigger has been selected.
Trigger level
It sets the value to be assumed by the variable to start capturing data.
It is taken into account when trigger has been selected.
Position (%)
It is taken into account when Trigger has been selected.
It is defined as a percentage, between 0% and 100%. It indicates the number of
samples to be taken before the Trigger. For example, a 10% position indicates that
10% of the total number of programmed samples will be taken before the Trigger and
the remaining 90% after that instant.
The Trigger condition is evaluated after gathering the indicated % of samples. If the
position is defined as 50% and the Trigger condition takes place after taking 10% of
the samples, it is ignored until capturing 50% of the samples.
Machine parameters to be set
In this area of the data window, it is possible to directly change the values of up to
20 machine parameters to be adjusted.