5 –parameters and variables– service, Parameters and variables– service, 5 –parameters and variables – Fagor America CNC8070 User Manual
Page 339: Service, Cnc 8070
Operating manual
CNC 8070
DDSSETUP
–Par
am
et
er
s and var
iabl
es– ser
v
ic
e.
14.
(S
OFT
V03.0
X
)
305
14.5
–Parameters and variables– service.
The command bar is located at the bottom of the window. See
Selection of the elements to be displayed
The
VIEW
softkey of the horizontal menu may be used to choose displaying either
the parameters and variables, only the parameters or only the variables.
From the top of the window, it is possible to select:
• The drive whose parameters and/or variables are to be consulted.
• The group of parameters and/or variables to work with. Once selected, the list will
show the elements of the selected group.
• The set of parameters to be consulted. Those parameters and/or variables that
have sets will display the values of that set. Also, its identifier will show the selected
set (e.g. for set 4 of the variable SP2, it will show SP2.4)
Parameters with a set will not be affected by the change.
List of variables and parameters
The list of variables and parameters offers the following information.
• Mnemonic of the variable or of the parameter.
• Current value at the drive.
• Units being used.
• Valid range of values. If it is a string of characters, it will show the maximum length
permitted.
• Sercos identifier.
• Name of the variable or of the parameter.
Editing the values
The values, of parameters or variables with write permission are edited in the Value
field. If the new value is accepted, the list shows the change.
The changes are saved in the drive's RAM memory. To save the change permanently,
use the "
DATA
+
FLASH
" option of the horizontal menu.
This service shows the list of parameters and/or variables of the drive. It is selected
with the
VIEW
softkey of the horizontal menu.