9 command generator, Command generator, Cnc 8070 – Fagor America CNC8070 User Manual

Page 345

Advertising
background image

‡ ‡ ‡

‡ ‡ ‡

‡ ‡ ‡

‡ ‡ ‡

Operating manual

CNC 8070

DDSSETUP

Com

m

and

ge

ner

a

tor

14.

(S

OFT

V03.0

X

)

311

14.9

Command generator

The fields to be configured at the generator are:

Shape

To select the type of signal to be generated with the drive
(sinusoidal or square).

Amplitude

Signal amplitude.

Frequency

Signal frequency.

Offset

Signal Offset.

Waves

Number of waves to generate. When set to 0 (zero), the
waves are generated continuously, without interruption.

Duty Cycle

Percentage of the wave at 1/0 (only on squarewaves).

The internal command generator is turned on and off using the lower buttons.

This option may be used to configure and start up the internal command generator
of the drive. In the configuration, it is possible to establish the shape of the signal,
its amplitude, period, etc.

It turns the command generator on.

It turns the command generator off.

Selected drive

Turn the command generator
on.

Configuration of the command
generator.