SETUP ASSI

STANCE

The

ci

rc

ul

ar

it

y (

roundne

ss)

t

e

st

13.

(S

OFT

V03.0

X

)

295

13.3.7 Validate the changes and save the configuration used

Validate the parameters

The new data is assumed by the CNC until the unit is turned off. Once the setup is
completed, the changes must be saved so they can be effective next time the CNC
is turned on.

When quitting the circularity test without having saved the parameters, the CNC will
show a message warning about it and will give a chance to save them.

Save and load the configuration

The system permits saving the current configuration into a file in ASCII format
(extension "TST"). This file only contains the configuration. It contains neither the
graphics nor the values of the machine parameters. When loading a configuration,
the parameters assume the value they have at the time.

Save the configuration

Press the

SAVE

softkey to save the current configuration. Select the folder and the

file name and press [ENTER]. If there is a configuration already saved with the same
name, it will ask whether it is to be replaced or not.

By default, the configuration is saved in the folder "C:\CNC8070 \MTB \DATA" or in
the last folder selected by the user.

Load the configuration

Press the

LOAD

softkey to load a previously saved configuration. Select the folder

and the file name and press [ENTER].

Use the

VALIDATE

softkey to save the data. The CNC saves the new values in the

CNC tables and/or in the drive tables accordingly.

The configuration saving option does not update the machine parameter
table. To do that, use the

VAL IDATE

softkey.