Profile II: Medium

This profile provides medium-speed data throughput and covers
approximately 4% of all application cases. It is appropriate for
applications where timing is not a critical factor. With the Medium
profile, network media access within a token group and
communication with external token groups is controlled by token
passing. These external token groups must also run Medium profiles.

Using LAN Switches and Hubs

When using a hub instead of a LAN switch to interconnect two or
more controllers of the same token group, network access within the
token group is no longer conducted by the hardware, but must be
managed by token passing.

IMPORTANT

In the Medium profile, a token group must be comprised of at
least two controllers to carry out token passing, otherwise the
controller configuration is erroneous. (Stop/Invalid
Configuration).

Minimum Ethernet Network Requirements for Medium & Cleanroom

Requirement

Definition

Medium

10 Mbps technology (10-Base T)

Hubs are used within the token groups and LAN switches connect one
token group to another.

Clean

No loss of data due to traffic overload, harsh environmental
conditions, or network defects.

IMPORTANT

The network must not be shared with other applications. Do not
use more than one programming terminal (recommended).
programming terminals increase network traffic, but do not
participate in token passing.