Guardplc 2000 power supply, Guardplc 2000 – Rockwell Automation 1755-OF8 GuardPLC Controller Systems User Manual

Page 26

Advertising
background image

26

Publication 1753-UM001C-EN-P - March 2010

Chapter 1 Overview of Safety Controllers

GuardPLC 2000 Controller, Power Supply, and I/O Modules

GuardPLC 2000 Power Supply

The 1755-PB720 power supply module provides two voltages

(3.3V DC and 5V DC) for the GuardPLC 2000 controller. They are
electrically isolated from the supply voltage, 24V DC.

1755-IB24XOB16 I/O Module

The 1755-IB24XOB16 digital input/output module provides 24 digital
inputs and 16 digital outputs. The status of each I/O signal is
displayed with a status indicator located on the right side of the front
plate connectors. Inputs and outputs are electrically isolated from the
supply voltage, 24V DC.

1755-IF8 Analog Input Module

The 1755-IF8 analog input module has eight inputs. These inputs can
be used as either eight single-ended inputs or four differential analog
inputs that are electrically isolated from the logic side of the GuardPLC
module. The measured input value can be either voltage or current. If
you use the input module for current, you need a shunt resistor. The
measured value is digitally transferred to the processor system as a
value between 0 and 2000.

FB2

FB1

L-

2

3

4

1

L-

L-

L-

L-

19

20

21

22

23

24

25

26

27

LS+

I17

I18

I19

I20

I21

I22

I23

I24

L-

O1

O2

O3

O4

O5

O6

O7

O8

L-

O9

O10

O11

O12

O13

O14

O15

O16

28

29

30

31

32

33

34

35

36

19

20

21

22

23

24

25

26

27

37

38

39

40

41

42

43

44

45

C-

B1

Z1

C1

C-

C-

C-

A1

C-

C-

B2

Z2

C2

C-

C-

C-

A2

C-

O1+

O2+

O2-

O3+

O3-

O4+

O4-

O1-

O5+

O6+

O6-

O7+

O7-

O8+

O8-

O5-

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

I1+

I2+

I-

I3+

I-

I4+

I-

I-

I5+/1-

I6+/2-

I-

I7+/3-

I-

I8+/4-

I-

I-

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

LS+

I1

I2

I3

I4

I5

I6

I7

I8

LS+

I9

I10

I11

I12

I13

I14

I15

I16

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

10/100BaseT

Tx

COL

FORCE

PROG

FAULT

RUN

STOP

RUN

ERR

RUN

RUN

RUN

ERR

RUN

ERR

ERR

1755-

IB24XOB16

1755-

IF8

1755-

OF8

1755-

HSC

1755-

L1

CPU

DIO

AI

AO

CO

PS

FAULT

2

1

3

24V

3,3V

FAULT

5V

RESTART

DC 24V

L-

L+

3V DC

LITH-BATT.

1755-

PB720

GuardPLC 2000

28

29

30

31

32

33

34

35

36

19

20

21

22

23

24

25

26

27

37

38

39

40

41

42

43

44

45

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

RUN

ERR

1755-

IB24XOB16

DIO

LS+

I17

I18

I19

I20

I21

I22

I23

I24

L-

O1

O2

O3

O4

O5

O6

O7

O8

L-

O9

O10

O11

O12

O13

O14

O15

O16

1

2

3

4

5

6

7

8

9

LS+

I1

I2

I3

I4

I5

I6

I7

I8

LS+

I9

I10

I11

I12

I13

I14

I15

I16

L-

2

3

4

1

L-

L-

L-

L-

19

20

21

22

23

24

25

26

27

C-

B1

Z1

C1

C-

C-

C-

A1

C-

C-

B2

Z2

C2

C-

C-

C-

A2

C-

1

2

3

4

5

6

7

8

9

10

11

12

13

14

15

16

17

18

RUN

ERR

1755-

HSC

CO

ERR

GuardPLC 2000 I/O Modules

GuardPLC 2000

Controller

GuardPLC 2000 Power Supply

Back-up Battery

Compartment

Ethernet Port

RS-232 Serial Port

(Active)

RS-232 Serial Port

(Inactive)