Guardplc 1753 digital i/o modules, Digital inputs, On bottom of module) – Rockwell Automation 1755-OF8 GuardPLC Controller Systems User Manual

Page 24

Advertising
background image

24

Publication 1753-UM001C-EN-P - March 2010

Chapter 1 Overview of Safety Controllers

GuardPLC 1753 Digital I/O Modules

L-

L-

L+

L+

1

LS+

LS+

LS+

LS+

LS+

L-

D1

2 3 4

13 14 15 16 17 18

5

L-

D1

6 7 8

19 20 21 22 23 24

9

L-

D1

10 11 12

25 26 27 28 29 30

13

L-

D1

14 15 16

31 32 33 34 35 36

17

L-

D1

18 19 20

37 38 39 40 41 42

19 20 21 22 23 24

13 14 15 16 23 24

1

L-

L-

DO

2 3 4

(2A)

1

2

3

4

5

6

1

2

3

4

5

6

7

L-

L-

DO

8 9 10

(2A)

7

8

9

10 11 12

7

8

9

10 11 12

25 26 27 28 29 30

31 32 33 34 35 36

37 38 39 40 41 42

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL

OSL

GuardPLC Ethernet

10/100 BaseT

1

(—)

2

(—)

1753-IB20OXB8

20 DC Inputs
8 DC Outputs

L-

L-

L+

L+

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL

OSL

1

LS+

LS+

LS+

L-

D1

2 3 4

1

2

3 4

5

6

5

L-

D1

6 7 8

19 20 21 22 23 24

9

L-

D1

10 11 12

L- 1

L-

2 3 4

19 20 21 22 23 24

1

2

3 4

5

6

7 8

9 10 11 12

7 8

9 10 11 12

13 14 15 16 17 18

13 14 15 16 17 18

LS+ 13

L-

14 15 16

25 26 27 28 29 30

25 26 27 28 29 30

GuardPLC Ethernet

10/100 BaseT

1

(—)

2

(—)

1753-IB16

16 DC Inputs

4 Pulse Test Sources

PO PULSE TEST

L-

L-

L+

L+

1

L-

L-

DO

2 3 4

1

2

3

4

5

6

1

2

3

4

5

6

5

L-

L-

DO

6 7 8

7

8

9

10 11 12

7

8

9

10 11 12

9

L-

L-

DO

10 11 12

13 14 15 16 17 18

13 14 15 16 17 18

13

L-

L-

DO

14 15 16

19 20 21 22 23 24

19 20 21 22 23 24

24V DC

L-

L-

L+

L+

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL

OSL

GuardPLC Ethernet

10/100 BaseT

1

(—)

2

(—)

1753-OB16

16 DC Outputs

L-

L-

L+

L+

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL

OSL

1

LS+

L-

S+
DO-

PO PULSE TEST

DO

(2A)

2 4 8-

1

2

3 4

5

6

1

L-

2 3 4+

L-

DO

(2A)

5

L-

6 7 8+

LS+

DI

5

L-

6 7 8

19 20 21 22 23 24

7 8

9 10 11 12

13 14 15 16 17 18

LS+

DI

1

L-

2 3 4

25 26 27 28 29 30

GuardPLC Ethernet

10/100 BaseT

1

(—)

2

(—)

1753-IB8XOB8

8 DC Inputs

8 DC Outputs

PO PULSE TEST

1 1 1 1 2 2 2 2

L-

L-

L+

L+

1

2

3

4

5

6

8

7

S+

DO

DO

S+ S+ S+ S- S- S- S-

24V DC

RUN

24 V DC

PROG

ERROR

FAULT

FORCE

BL

OSL

2

1

DO +

-

4

3

6

5

8

7

GuardPLC Ethernet

10/100 BaseT

1

(—)

2

(—)

1753-IB16 OXB8

16 DC Inputs
8 DC Outputs

LS+ LS+ 1

2

3

4

L-

L-

33 34 35 36 37 38 39 40 41 42

43 44 45 46 47 48 49 50 51 52

53 54 55 56 57 58 59 60 61 62

63 64 65 66 67 68 69 70 71 72

9 10 11 12 13 14

16

15

1- 1+ 2- 2+ 3- 3+

4+

4-

5- 5+ 6- 6+ 7- 7+

8+

8-

17 18 19 20 21 22

24

23

25 26 27 28 29 30

32

31

LS+ LS+ 5

6

7

8

L-

L-

LS+ LS+ 9 10 11 12

L-

L-

LS+ LS+ 13 14 15 16

L-

L-

Digital Outputs

Voltage Supply Connection

Ethernet Ports

(on Bottom of Module)

Digital Inputs

Digital Inputs

Voltage Supply Connection

Ethernet Ports

(on Bottom of Module)

Pulse Test Sources

Digital

Outputs

Voltage Supply

Connection

Ethernet Ports

(on Bottom of Module)

Voltage Supply

Connection

Digital

Outputs

Digital Outputs

1753-IB20XOB8 Module

1753-IB16 Module

1753-OB16 Module

1753-IB8XOB8 Module

1753-IB16XOB8 Module

Ethernet Ports

(on Bottom of Module)

Voltage Supply

Connection

Digital Outputs

Pulse Test Sources

Digital Inputs

Ethernet Ports

(on Bottom of Module)

Digital Inputs

Voltage Supply

Connection

Digital Outputs

Pulse Test Sources

Advertising