Communicate with ASCII Devices

Introduction

Connect the Controller to an
ASCII Device

For the sole purpose of sending the status of the signals from the
GuardPLC controller to an external device, you can connect an
intelligent ASCII device to the GuardPLC controller’s serial port. This
ASCII connection is one-way from the GuardPLC controller (slave) to
the master device. You cannot program the GuardPLC controller or
change the values in the GuardPLC controller by using this port.

To use the ASCII function, signals that you wish to send out the serial
port must be connected to placeholders in the ASCII-protocol Connect
Signals dialog box. These signals are then capable of being sent out
the serial port if a command string is properly received from the
master. The command string includes a starting address and number
of signals to be sent. The GuardPLC controller replies to this
command string by sending the values of these signals out the serial
port in an ASCII string.

Connect to a GuardPLC 1200 Controller

Use a 1761-CBL-PM02 series C cable to connect to the serial port. The
mini-DIN connector attaches to the controller. The other end is a 9-pin

Topic

Page

Connect the Controller to an ASCII Device

265

Configure the ASCII Serial Port

268

Connect Signals

269

ASCII Protocol

270

PLC

1200

RS-232
ASCII
serial port