19 stdadd auto, 1 stdadd auto - overview, Stdadd auto – Metrohm tiamo 2.3 Patch 1 (process analysis) User Manual

Page 1098

Advertising
background image

5.6 Commands

■■■■■■■■■■■■■■■■■■■■■■

1082

■■■■■■■■

tiamo 2.3 Patch 1 (for Process Analysis)

5.6.4.19

STDADD auto

5.6.4.19.1

STDADD auto - Overview

Dialog window: Method

▶ STDADD auto ▶ Properties... ▶ STDADD auto - 'Com-

mand name'

Command for Standard addition with automatic addition of the stand-
ard addition solution from a dosing device in such a way that a constant
potential difference results.

Devices
This command can be executed with the following devices:

Titrando: 808, 809, 835, 836, 857, 904, 905, 906, 907

pH/Ion - Meter: 867

Robotic Titrosampler: 855

Appearance
The command has the following appearance:

Parameters
The parameters for the command STDADD auto are configured on the
following 3 tabs:

■

General/Hardware
Parameters for devices, dosing devices, sensors and stirrers.

■

Standard addition
Parameters for standard addition.

■

Measuring parameters
Parameters for setting the measurement procedure.

Standard addition curve
The standard addition curve with its associated evaluation data for a
determination is shown in the program part Database in the dialog win-
dow Calibration curve, which is opened with the menu item Determi-
nations

▶ Show calibration curve... or the symbol .

Command variables
The following command variables are generated in the method run by the
command STDADD auto and can be used in formulas under the desig-
nation 'Command name.Variable designation':