background image

4 Trial Operation

4.6.4 Operator Displays during Testing without Motor

4-16

4.6.4 Operator Displays during Testing without Motor

The status display changes as shown below to show that the test without a motor is being executed.

(1) Display on Panel Operator

∗ The test without a motor operation in progress is indicated with tSt.

  

Note: The test without a motor status is not displayed during alarm occurs (A.†††).

(2) Display on Digital Operator

An asterisk (

∗) is displayed before status display to indicate the test without a motor operation is in progress.

(Example: Status of power to the servomotor is OFF)

Note: The test without a motor status is not displayed during alarm occurs (A.†††).

Display

Status

run ⇔ tSt

Power is supplied to the servomotor.

bb ⇔ tSt

Power to the servomotor is OFF.

Pot ⇒ not ⇒ tSt

Forward or reverse run is prohibited.

Pot ⇔ tSt

Forward run is prohibited.

not ⇔ tSt

Reverse run is prohibited.

Hbb ⇔ tSt

In hard-wire base block (safety) state.

Displayed alternately

Analog

Display

Status

*RUN

Power is supplied to the servomotor.

*BB

Power to the servomotor is OFF.

*PT NT

Forward or reverse run is prohibited.

*P-OT

Forward run is prohibited.

*N-OT

Reverse run is prohibited.

*HBB

In hard-wire base block (safety) state.

∗ B B

− P R M / M O N −

U n 0 0 0 =

0

0 0 0 0 0

U n 0 0 2 =

0

0 0 0 0 0

U n 0 0 8 =

0

0 0 0 0 0 0 0 0 0 0

U n 0 0 D =

0

0 0 0 0 0 0 0 0 0 0