Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 408

Advertising
background image

11 Appendix

11.2.2 Parameters

11-32

Pn515

2

Input Signal Selection 6

0000 to FFFF

8888

After restart

Setup

Pn517

2

Reserved (Do not change.)

0000

Pn51B

4

Excessive Error Level between
Servomotor and Load Positions

0 to

1073741824

1

reference

unit

1000

Immediately

Setup

9.3.6

Pn51E

2

Excessive Position Error
Warning Level

10 to 100

1%

100

Immediately

Setup

10.2.1

Pn520

4

Excessive Position Error Alarm
Level

1 to

1073741823

1

reference

unit

5242880

Immediately

Setup

6.1.4

10.1.1

Pn522

4

Positioning Completed Width

0 to

1073741824

1

reference

unit

7

Immediately

Setup

5.4.6

Pn524

4

NEAR Signal Width

1 to

1073741824

1

reference

unit

1073741824

Immediately

Setup

5.4.7

Pn526

4

Excessive Position Error Alarm
Level at Servo ON

1 to

1073741823

1

reference

unit

5242880

Immediately

Setup

6.1.4

Pn528

2

Excessive Position Error
Warning Level at Servo ON

10 to 100

1%

100

Immediately

Setup

Pn529

2

Speed Limit Level at Servo ON

0 to 10000

1 min

-1

10000

Immediately

Setup

Pn52A

2

Multiplier per One Fully-closed
Rotation

0 to 100

1%

20

Immediately

Tuning

9.3.6

Pn52B

2

Overload Warning Level

1 to 100

1%

20

Immediately

Setup

5.2.8

Pn52C

2

Derating of Base Current at
Detecting Overload of Motor

10 to 100

1%

100

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Reserved (Do not change.)

Reference Pulse Input Multiplication Switching Input Signal Mapping (/PSEL)

Reference

Section

0

Active when CN1-40 input signal is ON (closed).

5.4.3

1

Active when CN1-41 input signal is ON (closed).

2

Active when CN1-42 input signal is ON (closed).

3

Active when CN1-43 input signal is ON (closed).

4

Active when CN1-44 input signal is ON (closed).

5

Active when CN1-45 input signal is ON (closed).

6

Active when CN1-46 input signal is ON (closed).

7

Always active (fixed).

8

Not active (fixed).

9

Active when CN1-40 input signal is OFF (open).

A

Active when CN1-41 input signal is OFF (open).

B

Active when CN1-42 input signal is OFF (open).

C

Active when CN1-43 input signal is OFF (open).

D

Active when CN1-44 input signal is OFF (open).

E

Active when CN1-45 input signal is OFF (open).

F

Active when CN1-46 input signal is OFF (open).

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.