10 Troubleshooting

10.1.2 Troubleshooting of Alarms

10-18

A.d00:
Position Error Over-

flow
(Position error exceeded

the value set in the

excessive position error

alarm level (Pn520).)

The servomotor U, V, and W wir-

ings is faulty.

Check the servomotor main circuit

cable connection.

Confirm that there is no contact

fault in the motor wiring or encoder

wiring.

The frequency of the position ref-

erence pulse is too high.

Reduce the reference pulse fre-

quency, and operate the SERVO-

PACK.

Reduce the position reference pulse

frequency or acceleration of posi-

tion reference. Or, reconsider the

electronic gear ratio.

The acceleration of the position

reference is too high.

Reduce the reference acceleration,

and operate the SERVOPACK.

Apply the smoothing function, such

as using position reference accelera-

tion/deceleration time constant

(Pn216).

Setting of the excessive position

error alarm level (Pn520) is low

against the operating condition.

Check the alarm level (Pn520) to

see if it is set to an appropriate

value.

Set the Pn520 to proper value.

A SERVOPACK fault occurred.

Turn the power supply OFF and

then ON again. If the alarm still

occurs, the SERVOPACK may be

faulty. Replace the SERVOPACK.

A.d01:
Position Error Over-

flow Alarm at Servo

ON

This alarm occurs if the servomo-
tor power is turned ON when the
position error is greater than the
set value of Pn526 while the ser-

vomotor power is OFF.

Check the position error amount

(Un008) while the servomotor

power is OFF.

Set position error to be cleared

while the servomotor power is OFF.
Or, correct the excessive position

error alarm level at servo ON

(Pn526).

A.d02:
Position Error Over-

flow Alarm by Speed

Limit at Servo ON

When the position errors remain
in the error counter, Pn529 limits
the speed if the servomotor power
is ON. If Pn529 limits the speed
in such a state, this alarm occurs
when reference pulses are input
and the number of position errors
exceeds the value set for the
excessive position error alarm
level (Pn520).

Set position error to be cleared

while the servomotor power is OFF.
Or, correct the excessive position

error alarm level (Pn520).
Or, adjust the speed limit level at

servo ON (Pn529).

A.d10:
Motor-load Position

Error Overflow

Motor rotation direction and

external encoder installation

direction are opposite.

Check the servomotor rotation

direction and the external encoder

installation direction.

Install the external encoder in the

opposite direction, or change the

setting of the external encoder

usage method (Pn002.3) to reverse

the direction.

Mounting of the load (e.g., stage)

and external encoder joint instal-

lation are incorrect.

Check the external encoder

mechanical connection.

Check the mechanical joints.

A.E71:
Safety Option Module

Detection Failure

The connection between the
SERVOPACK and the safety
option module is faulty.

Check the connection between the
SERVOPACK and the safety option
module.

Correctly connect the safety option
module.

The safety option module was
disconnected.

Execute Fn014 (Resetting configu-
ration error of option module) with
using the digital operator or Sig-
maWin+ and turn the power supply
OFF and then ON again.

A safety option module fault
occurred.

Replace the safety option module.

A SERVOPACK fault occurred.

Replace the SERVOPACK.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions