6.1 Type of Adjustments and Basic Adjustment Procedure

6-11

6

Adjustm

e

nts

Related Alarms

When an alarm occurs, refer to 10 Troubleshooting and take the corrective actions.

Alarm Dis-

play

Alarm Name

Meaning

A.d01

Position Error Overflow
Alarm at Servo ON

This alarm occurs if the servomotor power is turned ON when the position
error is greater than the set value of Pn526 while the servomotor power is
OFF.

A.d02

Position Error Overflow
Alarm by Speed Limit at
Servo ON

When the position errors remain in the error counter, Pn529 limits the speed
if the servomotor power is turned ON. If Pn529 limits the speed in such a
state, this alarm occurs when reference pulses are input and the number of
position errors exceeds the value set for the excessive position error alarm

level (Pn520).