3.1.2 Using a Standard Power Supply (Single-phase 100 V, Three-phase 200 V, or Three-phase 400 V)

3-10

2. The following restrictions apply to UL standard compliance conditions.

SERVOPACK Model SGDV-

Restrictions

180A, 200A

Available rated current for modeled-case circuit breaker: 40 A or less

330A

• Available rated current for non-time delay fuse: 70 A or less
• Available rated current for time delay fuse: 40 A or less
• Do not use single wires.

470A, 550A

• Available rated current for molded-case circuit breaker: 60 A or less
• Available rated current for non-time delay fuse or time delay fuse: 60 A or

less

590A, 780A

• Available rated current for molded-case circuit breaker: 100 A or less.
• Available rated current for non-time delay fuse or time delay fuse: 100 A or

less

(Available rated current for a non-time delay, Class J fuse or a faster fuse: 125
A or less)

210D, 260D

• Available rated current for molded-case circuit breaker: 60 A or less.
• Available rated current for non-time-delay fuse: 60 A or less.
• Available rated current for time delay fuse: 35 A or less

280D, 370D

• Available rated current for molded-case circuit breaker: 80 A or less
• Available rated current for non-time delay fuse: 125 A or less
• Available rated current for time delay fuse: 75 A or less

Advertising