2 parameters – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 386

Advertising
background image

11 Appendix

11.2.2 Parameters

11-10

11.2.2 Parameters

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Pn000

2

Basic Function Select Switch 0 0000 to 00B3

0000

After restart

Setup

Direction Selection

Reference

Section

0

Sets CCW as forward direction.

5.2.2

1

Sets CW as forward direction. (Reverse Rotation Mode)

2 to 3

Reserved (Do not change.)

Control Method Selection

Reference

Section

0

Speed control (analog reference)

5.7

1

Position control (pulse train reference)

2

Torque control (analog reference)

3

Internal set speed control (contact reference)

4

Internal set speed control (contact reference)

↔ Speed control (analog reference)

5

Internal set speed control (contact reference)

↔ Position control (pulse train reference)

6

Internal set speed control (contact reference)

↔ Torque control (analog reference)

7

Position control (pulse train reference)

↔ Speed control (analog reference)

8

Position control (pulse train reference)

↔ Torque control (analog reference)

9

Torque control (analog reference)

↔ Speed control (analog reference)

A

Speed control (analog reference)

↔ Speed control with zero clamp function

B

Position control (pulse train reference)

↔ Position control with reference pulse inhibit

function

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.