6 Adjustments

6.2.3 Related Parameters

6-18

6.2.3 Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn170

Tuning-less Function Related Switch

No

Yes

Pn401

Torque Reference Filter Time Constant

No

Yes

Pn40C

2nd Notch Filter Frequency

No

Yes

Pn40D

2nd Notch Filter Q Value

No

Yes