Caution, 4) overtravel warning function, Analog – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 122

Advertising
background image

5 Operation

5.2.3 Overtravel

5-8

When Servomotor Stopping Method is Set to Decelerate to Stop

Emergency stop torque can be set with Pn406.

• The setting unit is a percentage of the rated torque.
• The factory setting is 800% so that the setting is large enough a value to operate the servomotor at maximum

torque. The maximum value of emergency stop torque that is actually available, however, is limited to the
maximum torque of the servomotor.

(4) Overtravel Warning Function

This function detects an overtravel warning (A.9A0) if overtravel occurs while the servomotor power is ON.

Using this function enables notifying the host controller when the SERVOPACK detects overtravel even if the

overtravel signal is ON only momentarily.

To use the overtravel warning function, set digit 4 of Pn00D to 1 (detects overtravel warning).

Note: The overtravel warning function is supported by software version 001A or later. The software version can be

checked with Fn012. For details, refer to 7.14 Software Version Display (Fn012).

Warning Output Timing

<Notes>

• Warnings are detected for overtravel in the same direction as the reference.
• Warnings are not detected for overtravel in the reverse direction from the reference.

Example:A warning will not be output for a forward reference even if the N-OT signal (reverse run prohibited)

turns ON.

• A warning can be detected in either the forward or reverse direction, when there is no reference.
• A warning will not be detected when the servomotor power is OFF even if overtravel occurs.
• A warning will not be detected when the servomotor power changes from OFF to ON even if overtravel status

exists.

• The warning output will be held for one second after the overtravel status no longer exists and it will then be

cleared automatically.

Related Parameter

Pn406

Emergency Stop Torque

 

 

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Speed

Position

Torque

CAUTION

• The overtravel warning function only detects warnings. It does not affect on stopping for overtravel or

motion operations at the host controller. The next step (e.g., the next motion or other command) can be

executed even if an overtravel warning exists. However, depending on the processing specifications and

programming for warnings in the host controller, operation may be affected when an overtravel warning

occurs (e.g., motion may stop or not stop). Confirm the specifications and programming in the host control-

ler.

• When an overtravel occurs, the SERVOPACK will perform stop processing for overtravel. Therefore, when

an overtravel warning occurs, the servomotor may not reach the target position specified by the host con-

troller. Check the feedback position to make sure that the axis is stopped at a safe position.

Overtravel input signal

(P-OT, N-OT signals)

Overtravel warning

(A.9A0)

Servomotor power

Warning not detected.

OFF

Disabled

Disabled

Enabled

Enabled

Disabled

ON

Normal status

Normal status

Warning status

One second

Warning status automatically cleared.

Analog

Parameter

Meaning

When Enabled Classification

Pn00D

n.0
[Factory setting]

Does not detect overtravel warning.

Immediately

Setup

n.1

Detects overtravel warning.

Advertising