7.16 Vibration Detection Level Initialization (Fn01B)

7-27

7

Util

ity Fu

nctions (Fn

)

(2) Operating Procedure

Use the following procedure.

(3) Related Parameters

The following table lists parameters related to this function and their possibility of being changed while exe-

cuting this function or of being changed automatically after executing this function.

• Parameters related to this function

These are parameters that are used or referenced when executing this function.

• Allowed changes during execution of this function

Yes : Parameters can be changed using SigmaWin+ while this function is being executed.

No : Parameters cannot be changed using SigmaWin+ while this function is being executed.

• Automatic changes after execution of this function

Yes : Parameter set values are automatically set or adjusted after execution of this function.
No : Parameter set values are not automatically set or adjusted after execution of this function.

Step

Display after Opera-

tion

Keys

Operation

1

Press the MODE/SET Key to select the utility function.

2

Press the UP or DOWN Key to select Fn01b.

3

Press the DATA/SHIFT Key for approximately one second.
The display shown on the left appears.

4

Display flashes.

Press the MODE/SET Key for approximately one second.
The display shown on the left will flash and the vibration

level will be detected and refreshed.
Notes:

• Operate the SERVOPACK with the references that will

be used for actual operation.

• If the servomotor is rotating at 10% or less of the maxi-

mum speed, "Error" will be displayed.

5

Press the MODE/SET Key again at a suitable time to com-
plete vibration detection and refreshing the setting. This
will enable the setting. If the setting has been completed
normally, "donE" will be displayed. If there was a setting
failure, "Error" will be displayed.

6

Press the DATA/SHIFT Key for approximately one second.
"Fn01b" is displayed again.

MODE/SET

DATA/

MODE/SET

DATA/

MODE/SET

DATA/

MODE/SET

DATA/

MODE/SET

DATA/

MODE/SET

DATA/

Parameter

Name

Mid-execution

changes

Automatic

changes

Pn311

Vibration Detection Sensitivity

Yes

No

Pn312

Vibration Detection Level

No

Yes

Advertising