11 Appendix

11.2.2 Parameters

11-26

Pn50A

2

Input Signal Selection 1

0000 to FFF1

2100

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Input Signal Allocation Mode

Reference

Section

0

Uses the sequence input signal terminals with the factory-set allocations.

3.3.1

1

Changes the sequence input signal allocation for each signal.

Servo ON (/S-ON) Signal Mapping
Signal Polarity: Normal; Servomotor power ON when ON (closed)
Signal Polarity: Reverse; Servomotor power OFF when OFF (open)

Reference

Section

0

Active when CN1-40 input signal is ON (closed).

5.2.1

1

Active when CN1-41 input signal is ON (closed).

2

Active when CN1-42 input signal is ON (closed).

3

Active when CN1-43 input signal is ON (closed).

4

Active when CN1-44 input signal is ON (closed).

5

Active when CN1-45 input signal is ON (closed).

6

Active when CN1-46 input signal is ON (closed).

7

Always active (fixed).

8

Not active (fixed).

9

Active when CN1-40 input signal is OFF (open).

A

Active when CN1-41 input signal is OFF (open).

B

Active when CN1-42 input signal is OFF (open).

C

Active when CN1-43 input signal is OFF (open).

D

Active when CN1-44 input signal is OFF (open).

E

Active when CN1-45 input signal is OFF (open).

F

Active when CN1-46 input signal is OFF (open).

/P-CON Signal Mapping (P control when ON (closed))

Reference

Section

0 to F

Same as Servo ON Signal (/S-ON) Mapping.

6.9.4

P-OT Signal Mapping (Forward run prohibited when OFF (open))

Reference

Section

0

Forward run allowed when CN1-40 input signal is ON (closed).

5.2.3

1

Forward run allowed when CN1-41 input signal is ON (closed).

2

Forward run allowed when CN1-42 input signal is ON (closed).

3

Forward run allowed when CN1-43 input signal is ON (closed).

4

Forward run allowed when CN1-44 input signal is ON (closed).

5

Forward run allowed when CN1-45 input signal is ON (closed).

6

Forward run allowed when CN1-46 input signal is ON (closed).

7

Forward run prohibited.

8

Forward run allowed.

9

Forward run allowed when CN1-40 input signal is OFF (open).

A

Forward run allowed when CN1-41 input signal is OFF (open).

B

Forward run allowed when CN1-42 input signal is OFF (open).

C

Forward run allowed when CN1-43 input signal is OFF (open).

D

Forward run allowed when CN1-44 input signal is OFF (open).

E

Forward run allowed when CN1-45 input signal is OFF (open).

F

Forward run allowed when CN1-46 input signal is OFF (open).

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising