1 motor rotation direction – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 339

Advertising
background image

9.3 Parameter Settings for Fully-closed Loop Control

9-13

9

Fu

lly-close

d L

oop

Co

ntro

l

9.3.1 Motor Rotation Direction

The motor rotation direction can be set. To perform fully-closed loop control, it is necessary to set the motor

rotation direction with both Pn000.0 (motor rotation direction) and Pn002.3 (external encoder usage).

(1) Setting Parameter Pn000.0

The standard setting for forward rotation is counterclockwise (CCW) as viewed from the load end of the ser-
vomotor.

Note: SigmaWin+ trace waveforms are shown in the above table.

(2) Setting Parameter Pn002.3

∗ The mode will be switched to semi-closed position control if Pn002.3 is set to 0.

Parameter

Forward/

Reverse Ref-

erence

Direction of Motor Rotation and Encoder Output Pulse

Applicable

Overtravel

(OT)

Pn000

n.

0

Sets CCW as forward

direction.

[Factory setting]

Forward

Reference

P-OT

Reverse

Reference

N-OT

n.

1

Sets CW as forward

direction.

(Reverse Rotation

Mode)

Forward

Reference

P-OT

Reverse

Reference

N-OT

PAO

PBO

+

CCW

Phase B
advanced

Time

Encoder output pulse

Motor speed

Torque reference

Motor speed

PAO

PBO

+

CW

Phase A
advanced

Time

Encoder output pulse

Motor speed

Torque reference

Motor speed

PAO

PBO

+

CW

Phase B
advanced

Time

Encoder output pulse

Motor speed

Torque reference

Motor speed

PAO

PBO

+

CCW

Phase A
advanced

Encoder output pulse

Motor speed

Torque reference

Motor speed

Time

Parameter

Name

Meaning

When

Enabled

Classification

Pn002

n.0
[Factory setting]

External Encoder
Usage

Do not use external encoder.

*

After restart

Setup

n.1

Uses external encoder in forward rotation direc-
tion.

n.2

Reserved (Do not change.)

n.3

Uses external encoder in reversed rotation direc-

tion.

n.4

Reserved (Do not change.)

Advertising