11 Appendix

11.2.2 Parameters

11-12

Pn002

2

Application Function Select
Switch 2

0000 to 4113

0000

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

∗The mode will be switched to semi-closed position control if Pn002.3 is set to 0.

Speed/Position Control Option (T-REF Terminal Allocation)

Reference

Section

0

T-REF not allocated

1

Uses T-REF as an external torque limit input.

5.8.3

2

Uses T-REF as a torque feedforward input.

6.9.2

3

Uses T-REF as an external torque limit input when /P-CL and /N-CL are ON.

5.8.4

Torque Control Option (V-REF Terminal Allocation)

Reference

Section

0

V-REF not allocated

5.5.4

1

Uses V-REF as an external speed limit input.

Absolute Encoder Usage

Reference

Section

0

Uses absolute encoder as an absolute encoder.

5.9

1

Uses absolute encoder as an incremental encoder.

External Encoder Usage

Reference

Section

0

Do not use external encoder.

*

9.3.1

1

Uses external encoder in forward rotation direction.

2

Reserved (Do not change.)

3

Uses external encoder in reversed rotation direction.

4

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit