11.2 List of Parameters

11-23

11

Ap

pend

ix

Pn310

2

Vibration Detection Switch

0000 to 0002

0000

Immediately

Setup

Pn311

2

Vibration Detection
Sensibility

50 to 500

1%

100

Immediately

Tuning

7.16

Pn312

2

Vibration Detection Level

0 to 5000

1 min

-1

50

Immediately

Tuning

Pn324

2

Moment of Inertia Calculating
Start Level

0 to 20000

1%

300

Immediately

Setup

6.3.2

Pn400

2

Torque Reference Input Gain

10 to100

0.1 V/

rated

torque

30

Immediately

Setup

5.5.1
6.9.2

Pn401

2

Torque Reference Filter Time

Constant

0 to 65535

0.01 ms

100

Immediately

Tuning

6.9.6

Pn402

2

Forward Torque Limit

0 to 800

1%

800

Immediately

Setup

5.8.1

Pn403

2

Reverse Torque Limit

0 to 800

1%

800

Immediately

Setup

Pn404

2

Forward External Torque Limit

0 to 800

1%

100

Immediately

Setup

5.8.2,

5.8.4

Pn405

2

Reverse External Torque Limit

0 to 800

1%

100

Immediately

Setup

Pn406

2

Emergency Stop Torque

0 to 800

1%

800

Immediately

Setup

5.2.3

Pn407

2

Speed Limit during Torque
Control

0 to 10000

1 min

-1

10000

Immediately

Setup

5.5.4

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Vibration Detection Selection

Reference

Section

0

Does not detect vibration.

7.16

1

Outputs warning (A.911) when vibration is detected.

2

Outputs alarm (A.520) when vibration is detected.

Reserved (Do not change.)

Reserved (Do not change.)

Reserved (Do not change.)

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising