5 one-parameter tuning (fn203), 1 one-parameter tuning, Caution – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 240

Advertising
background image

6.5 One-parameter Tuning (Fn203)

6-37

6

Adjustm

e

nts

6.5 One-parameter Tuning (Fn203)

Adjustments with one-parameter tuning are described below.

6.5.1 One-parameter Tuning

One-parameter tuning is used to manually make tuning level adjustments during operation with a position ref-

erence or speed reference input from the host controller.

One-parameter tuning enables automatically setting related servo gain settings to balanced conditions by

adjusting one or two tuning levels.

One-parameter tuning performs the following adjustments.

• Gains (e.g., position loop gain and speed loop gain)
• Filters (torque reference filter and notch filter)
• Friction compensation
• Anti-resonance control

Refer to 6.5.4 Related Parameters for parameters used for adjustments.

Perform one-parameter tuning if satisfactory response characteristics is not obtained with advanced autotun-

ing or advanced autotuning by reference.

To fine-tune each servo gain after one-parameter tuning, refer to 6.8 Additional Adjustment Function.

CAUTION

• Vibration or overshooting may occur during adjustment. To ensure safety, perform one-parameter tuning in

a state where the SERVOPACK can come to an emergency stop at any time.

Advertising