5.9 Absolute Encoders

5-71

5

Ope

rat

ion

(1) Battery Replacement Procedure

Using an Encoder Cable with a Battery Case

1. Turn ON the control power supply of the SERVOPACK only.
2. Open the battery case cover.

3. Remove the old battery and mount the new JZSP-BA01 battery as shown below.

4. Close the battery case cover.

5. After replacing the battery, turn OFF the control power supply to clear the absolute encoder battery error

alarm (A.830).

6. Turn ON the control power supply again.
7. Check that the alarm display has been cleared and that the SERVOPACK operates normally.

If the SERVOPACK control power supply is turned OFF and the battery is disconnected
(which includes disconnecting the encoder cable), the absolute encoder data will be
deleted.

Open the cover.

Rotation

Mount the JZSP-BA01 battery.

To the SERVOPACK

Encoder Cable

Rotation

Close the cover.

Rotation