Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 367

Advertising
background image

10 Troubleshooting

10.1.2 Troubleshooting of Alarms

10-20

CPF00:
Digital Operator

Transmission Error 1

The contact between the digital

operator and the SERVOPACK is
faulty.

Check the connector contact.

Insert securely the connector or
replace the cable.

Malfunction caused by noise
interference.

Keep the digital operator or the
cable away from noise sources.

CPF01:
Digital Operator
Transmission Error 2

A digital operator fault occurred.

Disconnect the digital operator and
then re-connect it. If the alarm still
occurs, the digital operator may be

faulty. Replace the digital operator.

A SERVOPACK fault occurred.

Turn the power supply OFF and
then ON again. If the alarm still
occurs, the SERVOPACK may be
faulty. Replace the SERVOPACK.

∗2. These alarms are not stored in the alarm history and are displayed only in the panel display.

(cont’d)

Alarm Number:

Alarm Name

(Alarm Description)

Cause

Investigative Actions

Corrective Actions