Advertising
background image

3.1 Main Circuit Wiring

3-5

3

Wi

ring an

d Conn

ecti

on

(3) Typical Main Circuit Wiring Examples

Note the following points when designing the power ON sequence.

• Design the power ON sequence so that main power is turned OFF when a servo alarm signal (ALM) is output.
• The ALM signal is output for a maximum of five seconds when the control power is turned ON. Take this into consid-

eration when designing the power ON sequence. Design the sequence so the ALM signal is activated and the alarm
detection relay (1Ry) is turned OFF to stop the main circuit’s power supply to the SERVOPACK.

• Select the power supply specifications for the parts in accordance with the input power supply.

The typical main circuit wiring examples are shown below.

Single-phase 100 V, SGDV-

F (SGDV-R70F, -R90F, -2R1F, -2R8F)

• When turning ON the control power supply and the main circuit power supply, turn

them ON at the same time or turn the main circuit power supply after the control
power supply. When turning OFF the power supplies, first turn the power for the main
circuit OFF and then turn OFF the control power supply.

WARNING

• Do not touch the power supply terminals after turning OFF the power. High voltage may still remain in the

SERVOPACK, resulting in electric shock. When the voltage is discharged, the charge indicator will turn

OFF. Make sure the charge indicator is OFF before starting wiring or inspections.

Control power supply

ALM signal

5.0 s max.

L1

ENC

U

V

W

M

0 V

1Ry

+

31

32

1D

2KM

1KM

B2

L2

CN1

1QF

R T

+24 V

B1/

3SA

1Ry

1PL

1KM

2KM

1SA

1KM

1Ry

1KM

2SA

L1C
L2C

ALM

ALM

1FLT

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay

SERVOPACK

SGDV-

F

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

Analog