5.8 Limiting Torque

5-59

5

Ope

rat

ion

5.8 Limiting Torque

The SERVOPACK provides the following four methods for limiting output torque to protect the machine.

Note: The maximum torque of the servomotor is used when the set value exceeds the maximum torque.

5.8.1 Internal Torque Limit

This function always limits maximum output torque by setting values of following parameters.

The setting unit is a percentage of the rated torque.

Note: If the settings of Pn402 and Pn403 are too low, the torque may be insufficient for acceleration or deceleration of the

servomotor.

Torque waveform

Limiting Method

Description

Reference Sec-

tion

Internal torque limit

Always limits torque by setting the parameter.

5.8.1

External torque limit

Limits torque by input signal from the host controller.

5.8.2

Torque limiting by analog
voltage reference

Assigns a torque limit by analog voltage reference.

5.8.3

External torque limit + Torque
limiting by analog voltage ref-
erence

Combines torque limiting by an external input and by analog volt-
age reference.

5.8.4

Pn402

Forward Torque Limit

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Pn403

Reverse Torque Limit

Classification

Setting Range

Setting Unit

Factory Setting

When Enabled

0 to 800

1%

800

Immediately

Setup

Speed

Position

Torque

Speed

Position

Torque

Speed

Maximum torque

t

Speed

Pn403

Pn402

Limiting torque

t

No Internal Torque Limit

(Maximum torque can be output)

Internal Torque Limit

Rotation