11.2 List of Parameters

11-21

11

Ap

pend

ix

Pn200

2

Position Control Reference
Form Selection Switch

0000 to 2236

0000

After restart

Setup

Pn205

2

Multiturn Limit Setting

0 to 65535

1 rev

65535

After restart

Setup

5.9.6

Pn207

2

Position Control Function
Switch

0000 to 2210

0000

After restart

Setup

(cont’d)

Parameter

No.

Size

Name

Setting

Range

Units

Factory

Setting

When

Enabled

Classification

Reference

Section

Reference Pulse Form

Reference

Section

0

Sign + Pulse train, positive logic

5.4.1

1

CW + CCW pulse train, positive logic

2

Two-phase pulse train with 90

° phase differential (phase A + phase B) ×1, positive logic

3

Two-phase pulse train with 90

° phase differential (phase A + phase B) ×2, positive logic

4

Two-phase pulse train with 90

° phase differential (phase A + phase B) ×4, positive logic

5

Sign + Pulse train, negative logic

6

CW + CCW pulse train, negative logic

Clear Signal Form

Reference

Section

0

Clears position error when the signal is at high level.

5.4.2

1

Clears position error at the rising edge of the signal.

2

Clears position error when the signal is at low level.

3

Clears position error at the falling edge of the signal.

Clear Operation

Reference

Section

0

Clears position error at the baseblock (servomotor power OFF or alarm occurred).

5.4.2

1

Does not clear position error (possible to clear error counter only with CLR signal).

2

Clears position error when an alarm occurs.

Filter Selection

Reference

Section

0

Uses reference input filter 1 for line driver signal (to 1 Mpps).

5.4.1

1

Uses reference input filter for open collector signal (to 200 kpps).

2

Uses reference input filter 2 for line driver signal (1 Mpps to 4 Mpps).

4th 3rd 2nd 1st

digit digit digit digit

n.

Reserved (Do not change.)

Position Control Option

Reference

Section

0

V-REF not allocated

6.9.3

1

Uses V-REF as a speed feedforward input.

Reserved (Do not change.)

/COIN Output Timing

Reference

Section

0

Outputs when the position error absolute value is the same or less than the
positioning completed width (Pn522).

5.4.6

1

Outputs when the position error absolute value is the same or less than the
positioning completed width (Pn522), and the reference after position reference
filtering is 0.

2

Outputs when the position error absolute value is the same or less than the
positioning completed width (Pn522), and the position reference input is 0.

4th 3rd 2nd 1st

digit digit digit digit

n.

Advertising