3 Wiring and Connection

3.1.4 Using the SERVOPACK with a DC Power Input

3-16

(3) Wiring Example with DC Power Supply Input

200-V SERVOPACK SGDV-

A

∗ Terminal names differ depending on model of SERVOPACK. Refer to (2) DC Power Supply Input Terminals for the

Main and Control Circuits.

400-V SERVOPACK SGDV-

D

∗ Terminal names differ depending on model of SERVOPACK. Refer to (2) DC Power Supply Input Terminals for the

Main and Control Circuits.

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

1PL

1KM

2KM

1SA

2SA

L1C

L2C

B1/

2

+

*

1FU

2KM

ENC

U

V

W

M

0 V

1Ry

1D

+24 V

1KM

AC/DC

1QF

R S T

3SA

+

31

32

CN1

1Ry

1KM

1Ry

1KM

ALM

ALM

1FLT

SGDV-

A

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

200-V SERVOPACK

Analog

24 V

0 V

B1

400-V SERVOPACK

SGDV-

D

2

1FU

2KM

ENC

U

V

W

M

0 V

1Ry

1D

+24 V

AC/DC

1QF

R S T

*

3SA

AC/DC

1PL

1KM

2KM

1SA

2SA

1KM

+

31

32

CN1

1Ry

1KM

1Ry

1KM

ALM

ALM

1FLT

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay

1PL: Indicator lamp
1SA: Surge absorber
2SA: Surge absorber
3SA: Surge absorber
1D: Flywheel diode

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

Analog

Advertising