5) power supply capacities and power losses, Analog, Servopack with single-phase, 200-v power supply – Yaskawa Sigma-5 User Manual: Design and Maintenance - Rotary Motors - Analog Voltage and Pulse Train Reference User Manual

Page 64

Advertising
background image

3.1 Main Circuit Wiring

3-13

3

Wi

ring an

d Conn

ecti

on

(4) Wiring Example with Single-phase 200-V Power Supply Input

SERVOPACK with Single-phase, 200-V Power Supply

Applicable SERVOPACK Model: SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5A, and -120A01A008000.

(5) Power Supply Capacities and Power Losses

The following table shows SERVOPACK’s power supply capacities and power losses when using single-
phase 200 V power supply.

∗ The official model number is SGDV-120A01A008000.

Note 1. SGDV-R70A, -R90A, -1R6A, and -2R8A SERVOPACKs do not have built-in regenerative resistors. If the regen-

erative energy exceeds the specified value, connect an external regenerative resistor between B1/ and B2.

2. Regenerative resistor power losses are allowable losses. Take the following action if this value is exceeded.

• Remove the lead or shorting bar between terminals B2 and B3 on the SERVOPACK main circuit of SGDV-

5R5A, -120A SERVOPACKs.

• Install an external regenerative resistor between external regenerative resistor connection terminals B1/ and

B2.

3. External regenerative resistors are not included.

1PL

1KM

2KM

1SA

2SA

L1

0 V

1Ry

1D

2KM

L3

B2
B3

L2

U

V

W

M

1QF

R T

1FLT

+24 V

ENC

1
2

L1C

1KM

L2C

3SA

B1/

+

31

32

CN1

1KM

1Ry

1KM

ALM

ALM

1Ry

1PL
1SA
2SA
3SA
1D:

: Indicator lamp
: Surge absorber
: Surge absorber
: Surge absorber
Flywheel diode

1QF: Molded-case circuit breaker
1FLT: Noise filter
1KM: Magnetic contactor (for control power supply)
2KM: Magnetic contactor (for main circuit power supply)
1Ry: Relay

SERVOPACK

SGDV-

A

(For servo

alarm display)

supply ON

Servo power

supply OFF

Servo power

Analog

Main Circuit

Power

Supply

Maximum

Applicable

Servomotor

Capacity

[kW]

SERVOPACK

Model

SGDV-

Power Supply

Capacity per

SERVOPACK

[kVA]

Output

Current

[Arms]

Main Circuit

Power Loss

[W]

Regenerative

Resistor

Power Loss

[W]

Control

Circuit

Power Loss

[W]

Total

Power

Loss

[W]

Single-phase,

200 V

0.05

R70A 0.2

0.66

5.2

17

22.2

0.1

R90A 0.3

0.91

7.4

24.4

0.2

1R6A 0.7

1.6

13.7

30.7

0.4

2R8A

1.2

2.8

24.9

41.9

0.75

5R5A

1.9

5.5

52.7

8

77.7

1.5

120A

*

4

11.6

68.2

10

22

100.2

Advertising