1 Outline

1-2

1.1 Σ-V Series SERVOPACKs

The

Σ-V Series SERVOPACKs are designed for applications that require frequent high-speed, high-pre-

cision positioning. The SERVOPACK makes the most of machine performance in the shortest time possi-

ble, thus contributing to improving productivity.

1.2 Part Names

This section describes the part names of SGDV SERVOPACK for analog voltage and pulse train reference.

CN5 Analog monitor connector

Used to monitor motor speed, torque
reference, and other values through
a special cable (option).

Panel display

Serial number

Used to display SERVOPACK
status, alarm numbers, and other
values when parameters are input.

Connects external regenerative resistors.

Used for control power supply input.

Panel operator keys

Used to set parameters.

Panel operator

Charge indicator

Front cover

CN3 Connector for digital operator

CN1 I/O signal connector

Used for reference input signals and sequence I/O signals.

CN7 Connector for personal computer (USB connector)

Communicates with a personal computer.
Use the connection cable (JZSP-CVS06-02-E).

CN2 Encoder connector

Connects the encoder in the servomotor.

Ground terminal

Be sure to connect to protect against electric shock.

Main circuit power supply terminals

Used for main circuit power supply input.

Control power supply terminals

Servomotor terminals

Connects the main circuit cable for servomotor.

SERVOPACK model

Regenerative resistor connecting terminals

Input voltage

CN8 Connector for safety function devices

DC reactor terminals for harmonic suppression

CN3

CN7

CN1

CN8

CN2

With front cover open

Nameplate (Found on side of SERVOPACK.)

Indicates the SERVOPACK model and ratings.

Lights when the main circuit power supply is ON
and stays lit as long as the internal capacitor
remains charged. Therefore, do not touch the
SERVOPACK even after the power supply is
turned OFF if the indicator is lit.
It may result in electric shock.

Refer to 2.1 Overview.

Refer to 3.1 Main Circuit Wiring.

Refer to 3.1 Main Circuit Wiring.

Refer to 3.6 Connecting Regenerative Resistors.

Refer to 3.7.3 Connecting a Reactor for

Harmonic Suppression.

Refer to 3.1 Main Circuit Wiring.

Refer to 3.1 Main Circuit Wiring.

Refer to 3.5 Encoder Connection.

Refer to 6.1.3 Monitoring Operation during Adjustment.

Refer to 2.1 Overview.

Refer to 1.6 SERVOPACK Model Designation.

Refer to 3.2 I/O Signal Connections.

Connects a safety function device.
Note: When not using the safety function, use the SERVO-

PACK with the safety function’s jumper connector
(JZSP-CVH05-E, provided as an accessory) inserted.
For the connecting method, refer to 3.2.2 Safety
Function Signal (CN8) Names and Functions
.
For details on how to use the safety function, refer to
5.11 Safety Function.

Connects a digital operator

(option, JUSP-OP05A-1-E) or a personal computer

(RS422).

Refer to

Σ-V Series Product Catalog (No.: KAEP

S800000 42) and

Σ-V Series User’s Manual, Opera-

tion of Digital Operator (No.: SIEP S800000 55).

45