2.4 Monitor Displays (Un

)

2-9

2

Pan

el Op

erator

2.4 Monitor Displays (Un

)

The monitor displays can be used for monitoring the reference values, I/O signal status, and SERVOPACK

internal status.

For details, refer to 8.2 Viewing Monitor Displays.

The panel operator displays numbers beginning with Un.

Display Example for Motor Rotating Speed

The following table outlines the procedures necessary to view the motor rotating speed (Un000).

Step

Display after

Operation

Keys

Operation

1

Press the MODE/SET Key to select the monitor display.

2

If Un000 is not displayed, press the UP or the DOWN Key
to select Un000.

3

Press the DATA/SHIFT Key for approximately one second
to display the data of Un000.

4

Press the DATA/SHIFT Key for approximately one second
to return to the display of monitor number (step 1).