6 Adjustments

6.1.3 Monitoring Operation during Adjustment

6-6

6.1.3 Monitoring Operation during Adjustment

Check the operating status of the machine and signal waveform when adjusting the servo gain. Connect a mea-

suring instrument, such as a memory recorder, to connector CN5 analog monitor connector on the SERVO-

PACK to monitor analog signal waveform.

The settings and parameters for monitoring analog signals are described in the following sections.

(1) Connector CN5 for Analog Monitor

To monitor analog signals, connect a measuring instrument with cable (JZSP-CA01-E) to the connector CN5.

(2) Monitor Signal

The shaded parts in the following diagram indicate analog output signals that can be monitored.

∗1. The reference pulse input multiplication switching function is supported by software version 001A or later.

∗2. Available when the fully-closed loop control is being used.

Line Color

Signal Name

Factory Setting

White

Analog monitor 1

Torque reference: 1 V/100% rated torque

Red

Analog monitor 2

Motor speed: 1 V/1000 min

-1

Black (2 lines)

GND

Analog monitor GND: 0 V

Probe

GND

Probe

GND

Measuring
Probe

Measuring
Probe

Measuring
instrument*

White

Red

Black

Black

CN5

CN5

JZSP-CA01-E

White

Red

Black

Black

„

Connection Example

∗ Measuring instrument is not included.

Analog

(U/V/W)

+

+

+

+

+

T-REF

V-REF

PULS
SIGN

+

+

1

SERVOPACK

Speed feedforward

Position reference speed

Position

amplifier error

Motor rotational

speed

Speed reference

Active gain

Torque

reference

Speed

conversion

Electronic

gear

Speed

loop

Current

loop

Fully-closed

loop control

Electronic

gear

1

Electronic

gear

Position loop

Torque feedforward

Error

counter

Error

counter

Error

counter

Load

M

Kp

Position error

Positioning
completed

Completion of position
reference

External encoder speed

Speed

conversion

Speed

conversion

Motor - load

position error

CN31

ENC

CN2

CN 1

External

ENC

*

2

*

2

*

2

*

2

Reference

Pulse

Multiplier

× n

*

1

45

Advertising